Power Output Ratings
|
|
Power Output (watts/foot)
vs. Pipe Temperature
|
|
Catalog No.
|
Pipe
Temperature (°F)
|
|
-50
|
0
|
50
|
100
|
150
|
250
|
392
|
446
|
|
HLT3, HLT23
|
3.8
|
3.4
|
3.0
|
2.6
|
2.2
|
1.4
|
0.0
|
|
|
HLT5, HLT25
|
6.4
|
5.7
|
5.0
|
4.3
|
3.6
|
2.2
|
0.0
|
|
|
HLT8, HLT28
|
10.5
|
9.3
|
8.0
|
6.8
|
5.5
|
3.0
|
0.0
|
|
|
HLT10, HLT210
|
12.5
|
11.3
|
10.0
|
8.8
|
7.5
|
5.0
|
0.0
|
|
|
HLT12,
HLT212
|
15.3
|
13.6
|
12.0
|
10.4
|
8.7
|
5.4
|
0.0
|
|
|
HLT15,
HLT215
|
18.7
|
16.8
|
15.0
|
13.1
|
11.3
|
7.6
|
0.0
|
|
|
HLT18,
HLT218
|
22.5
|
20.2
|
18.0
|
15.8
|
13.5
|
9.1
|
1.0
|
0.0
|
|
HLT20,
HLT220
|
24.3
|
22.1
|
20.0
|
17.8
|
15.7
|
11.4
|
3.0
|
0.0
|
The heater power output values shown above assume that the
heater has been attached to a steel pipe using fiberglass tape at
1 foot intervals and the entire pipe is then covered with thermal
insulation. Other attachment methods or pipe materials may affect
the power output of the heater. Please contact your Nelson
representative for assistance in these cases.
|
|