Power Output Ratings

Power Output (watts/foot) vs. Pipe Temperature

Catalog No.

Pipe Temperature (°F)

-50

0

50

100

150

250

392

446

HLT3, HLT23

3.8

3.4

3.0

2.6

2.2

1.4

0.0

 

HLT5, HLT25

6.4

5.7

5.0

4.3

3.6

2.2

0.0

 

HLT8, HLT28

10.5

9.3

8.0

6.8

5.5

3.0

0.0

 

HLT10, HLT210

12.5

11.3

10.0

8.8

7.5

5.0

0.0

 

HLT12, HLT212

15.3

13.6

12.0

10.4

8.7

5.4

0.0

 

HLT15, HLT215

18.7

16.8

15.0

13.1

11.3

7.6

0.0

 

HLT18, HLT218

22.5

20.2

18.0

15.8

13.5

9.1

1.0

0.0

HLT20, HLT220

24.3

22.1

20.0

17.8

15.7

11.4

3.0

0.0

The heater power output values shown above assume that the heater has been attached to a steel pipe using fiberglass tape at 1 foot intervals and the entire pipe is then covered with thermal insulation. Other attachment methods or pipe materials may affect the power output of the heater. Please contact your Nelson representative for assistance in these cases.

 